Flue Gas Analyzers

The E Instruments portable emissions analyzers are ideal for emissions monitoring, maintenance and tuning of combustion processes including boilers, burners, gas & diesel engines, turbines, furnaces, kilns, heaters, incinerators, and laboratory analysis. Each emissions analyzer is built with with a rugged and easy to use design for accurate and reliable measurements.

                  

 Click here to view enlarge       Click here to view enlarge              Click here to view enlarge               Click here to view enlarge

E1500 Combustion Analyser       E4400 Emission Analyser        E4500 Emission Analyser          E8500 Emission Analyser with chiller

 

 
  E1500 E4400 E4500 E5500 E8500 E8500-MK
  E1500 E4400 E4500 E5500 E8500 E8500-MK
 
Maximum Number of Sensors 2 4 4 5 9 9
Internal Memory
(Samples Stored)
2000 900 2000 1000 1000 1000
Draft/Differential Pressure Standard Standard Standard Standard Standard Standard
Gas Velocity   Optional Optional Optional Optional Optional
Built-In Printer
(Non-Thermal)
Standard, Non–Fading Paper Standard, Non–Thermal Standard, Non–Fading Paper Optional Remote
Wireless Printer
Optional Remote
Wireless Printer
Optional Remote
Wireless Printer
 
O2 Sensor
(0-25%)
Standard Standard Standard Standard Standard Standard
CO Sensor
(0-8000ppm)
Standard Standard Standard Standard Standard Standard
CO Dilution Auto-Range (automatic)   Standard,
up to 50,000ppm
Standard,
up to 50,000ppm
Standard,
up to 20,000ppm
Standard,
up to 20,000ppm
Standard,
up to 20,000ppm
CO2 Calculated
(0-99.9%)
Standard Standard Standard Standard Standard Standard
 
NO Sensor
(0-4000ppm)
  Standard Standard Standard Standard Standard
NO2 Sensor
(0-1000ppm)
  Optional Optional Optional Optional Standard
SO2 Sensor
(0-4000ppm)
  Optional Optional Optional Optional Standard
CxHy Sensor
Pellistor type (0-5%)
  Optional Optional      
H2S Sensor
(0-500ppm)
        Optional Optional
 
CO2 NDIR Sensor
(0-20%)
        Optional Standard
CxHy NDIR Sensor (0-3%)         Optional Standard
CO NDIR Sensor
(0-15%)
        Optional Standard
 
Built-In Peltier Chiller         Standard Standard
Bluetooth Wireless Communications Standard Standard Standard Standard Standard Standard
Software Package Standard Standard Standard Standard, Real–Time Standard, Real–Time Standard, Real–Time
 

 

 


Powered by :Hatch Concepts